LEXUS RX 300

1998 - 2003 of launch

Repair and operation of the car



Lexus RX 300
+ Lexus RX-300 cars
+ Administrations and methods of operation
+ Placing and regular maintenance of the car
+ Motor
- Cooling systems of the motor, heating, ventilation and air conditioning
   + System of cooling of motor
   - Systems of heating, ventilation and air conditioning
      General information
      Substitution, desmontagem and meeting of the block of K/V
      Removal, desmontagem, meeting and installation of the block of the supporter of a heater
      Check and substitution of the compressor and magnetic union K/V
      Removal and installation of the condenser K/V
      Checks of component ones of systems of heating and to / in
      Removal and installation of the unity of control
+ A system of provision of power and production of the carried out gases
+ Systems of electric equipment of the motor
+ Automatic exchange and differential interaxal
+ Transmission line
+ Brakes system
+ Support of the triangular form of interruption and direction
+ Body
+ Electric side equipment
+ Schematic diagrams of electric connections

8ca8824c

Checks of component ones of systems of heating and to / in

Wide valve

 ORDER OF REALIZATION

  1. The motor begins and leave us that it works in 1.500 revolutions per minute inside not less than 5 minutes then they secure what in an outline of the pressure of high pressure established for 13,6 ÷ 15.5 atm.
  2. In the bad functioning of the pressure of valve in an outline of the low pressure it will reduce to the zero. Check the reception and the final parties of the desumidificador of receiver – will be an identic temperature.

Pressure switch

 ORDER OF REALIZATION

  1. The motor begins and leave it to work for 1.500 revolutions per minute.
  2. Establish the very turns of the supporter of a heater and the least temperature.
  1. Taken of sensor of separate pressure.
  1. One to positive probe of an ohmmeter to contact 4, and negative – to the contact of 1 capture and to be secured of the modification of the condutividade in the modification of the pressure of the refrigerant liquid. So the control of the magnetic union happens.
1 - the Outline of low pressure
2 - there is a condutividade
3 - it has not condutividade
4 - the Outline of high pressure
  1. One to positive probe of an ohmmeter to contact 2, and negative – to contact with 3 captures and to make sure of the modification of the condutividade in the modification of the pressure of the refrigerant liquid. So the control of the supporter of condenser happens.
1 - there is a condutividade
2 - it has not condutividade

Main alternation of a heater

 ORDER OF REALIZATION

  1. Take the main alternation of a heater of the block of meeting (to see the electric equipment of Front Side).
  1. The available condutividade certifies between contacts 1 and 2, and also 3 and 4. 1 and 2 gives the tension of battery in contacts and the available condutividade certifies between contacts 3 and 5. In unsatisfactory checks results they substitute the alternation.

Alternation of the magnetic union

 ORDER OF REALIZATION

  1. Take the alternation of the magnetic union of the block of meeting in a compartment of reason (to see the electric equipment of Front Side).
  1. The available condutividade certifies between contacts 1 and 2. 1 and 2 gives the tension of battery in contacts and the available condutividade certifies between contacts 3 and 5. In unsatisfactory checks results they substitute the alternation.

Condenser supporter

 ORDER OF REALIZATION

  1. The motor begins, establish the very speed of the rotation of the supporter of a heater, the least temperature and include К/В.
  2. One secures that the supporter of the condenser works in the low speed in a temperature of OZh the 90th hail., and also with a pressure less than 15 atm. In a temperature of 95 a hail. and the pressure more than 15 atm – the supporter will work in the high speed.
  1. The supporter of the condenser separates the capture of electrical system and join the battery recarregável and the ampermeter to his contacts. It is secured what the krylchatka of the supporter spins lisamente. The indications of the ampermeter will do 9.8 ± 1.5 one in a temperature of 20 a hail.

System checks for contacts of ECU

The table of the tension in contacts of the unity of control of the useful system K/V below certain conditions happens down.

Contacts of the module of management to / in

Contacts

Wires color

Check conditions

Tension, in

<—><—>IG GND (C14-1 S14-11)

<—>- BRETANHA OF R-L

The ignition is included

10 ÷ 14

IN <—>GND <—>(C14-3 C14-11)

<—>- BRETANHA OF W-L

Constantly

10 ÷ 14

<—><—>BLW GND (C14-4 C14-11)

<—>- BRETANHA OF P-L

The ignition is included. The supporter's switch in the provision of "in"

1 ÷ 3

THERE <—>SG-5 <—>(C14-7 C14-16)

<—>- BRETANHA WR

25th extern temperature hail.

1,35 ÷ 1.75

40th extern temperature hail.

0,85 ÷ 1.25

<—><—>TR SG-3 (C13-3 S13-9)

<—>GR of G-W

Hall temperature I granulate 25.

1.8 ÷ 2.2

Hall temperature I granulate 40.

1.2 ÷ 1.6

<—><—>TPI SG-2 (C13-11 C13-1)

<—>GR B-W

The switch of REC corsets itself

3.5 ÷ 4.5

The switch of FRS corsets itself

0.5 ÷ 1.5

<—><—>AIR GND (C13-12 C14-11)

<—>GRÃ-BRETANHA

The switch of FRS corsets itself

10 ÷ 14

The switch of REC corsets itself

More low than 1,0

<—><—>I F GND (C13-13 C14-11)

<—>- BRETANHA OF GRÃ-BRETANHA-W

The switch of FRS corsets itself

More low than 1,0

The switch of REC corsets itself

10 ÷ 14

<—>TS S5-3 <—>(C13-15 C13-16)

<—>Y-B L

The sensor is illuminated with an electric lamp

0.8 ÷ 4.3

The sensor stretches out with rags

More low than 0,8

TO <—>SG-1 <—>(C12-1 C12-9)

<—>G-Y B-Y

Evaporador I granulate 0 of temperature.

2.0 ÷ 2.4

Evaporador I granulate 15 of temperature.

1.4 ÷ 1.8

<—><—>TPO SG-1 (C12-3 S12-9)

<—>LG-R B-Y

The ignition is included. CARA'S way is chosen

3.5 ÷ 4.5

The ignition is included. The switch of advanced DEF corsets itself

0.5 ÷ 1.5

<—><—>AOD GND (C12-4 C14-11)

<—>- BRETANHA OF LG-B

The ignition is included. CARA'S way is chosen

More low than 1,0

The ignition is included. The way DEF is chosen

10 ÷ 14

<—><—>AOF GND (C12-5 C14-11)

<—>GRÃ-BRETANHA

The ignition is included. CARA'S way is chosen

10 ÷ 14

The ignition is included. The way DEF is chosen

More low than 1,0

<—><—>TP SG-1 (C12-6 C12-9)

<—>THE B-Y

The ignition is included. Temperature regulator in the provision of the very cooling

3.5 ÷ 4.5

The ignition is included. Temperature regulator in the maximum provision to be heated

0.5 ÷ 1.5

<—><—>AMH GND (C12-7 S14-11)

<—>- BRETANHA OF Y-G

The ignition is included. Temperature regulator in the maximum provision to be heated

10 ÷ 14

The ignition is included. Temperature regulator in the provision of the very cooling

More low than 1,0

<—><—>AMC GND (C12-8 S14-11)

<—>GRÃ-BRETANHA

The ignition is included. Temperature regulator in the provision of the very cooling

10 ÷ 14

The ignition is included. Temperature regulator in the maximum provision to be heated

More low than 1,0